LS9-16
1
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- Use MY8-ADDA96 by setting the mode to AE.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.]]>
1
1420
1000
400
400
200
200
100
20.3999999999999
114
1
2;17;45;22;24;21;23;33;34
01V96i/01V96
1
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- Use MY8-ADDA96 in AE96 or AE mode.
Y56K/Y96K
- You cannot store scenes using Y56K or Y96K to 01V96 scene memory 97-99.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
MY16-CII
- MY16-CII is compliant with V2.30 or later (for 01V96).
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
710
310
200
200
200
200
0
12.57
118
1
17;45
01V
1
MY8-ADDA96
- Use MY8-ADDA96 by setting the mode to AE.
RN.141.MY
- Use RN.141.MY by setting the mode to 8AE.]]>
1
700
0
200
200
150
150
50
11
123
2
6;9;10;11;12;14;16;17;18;19;36;20;39;41;45;46;21;23;28;26;38;40;25;44;42;33;34;29;30;47;48
AD824
1
RN.141.MY
- Use RN.141.MY by setting the mode to 8AE.]]>
1
700
0
200
200
150
150
20
10.4
202
2
1;2;3;4;5;6;7;9;10;11;12;14;16;17;18;19;36;20;39;41;45;24;46;21;23;27;28;38;40;25;44;42;33;34;47;48
DA824
1
RN.141.MY
- Use RN.141.MY by setting the mode to 8AE.]]>
1
700
0
200
200
150
150
20
10.4
203
2
1;2;3;4;5;6;7;9;10;11;12;14;16;17;18;19;36;20;39;41;45;24;46;21;23;27;28;38;40;25;44;42;33;34;47;48
AW2400
1
1
740
310
200
110
80
90
50
8.82
503
1
2;7;9;17;18;19;36;20;39;41;45;22;46;21;23;27;26;38;40;25;44;43;37;42;33;29;30;48
AW2816
1
Y56K/Y96K
- AW2816 firmware must be V1.1 or later to use Y56K
- Y96K will be recognized as Y56K.
Pivitec e16i/o-MY
- AW2816 only support 8 channels and will not be compatible with the initial release of the e16i/o-MY card.]]>
1
500
500
200
110
150
150
50
5.79999999999999
502
1
6;7;9;10;11;12;14;16;17;18;19;36;20;39;41;45;24;46;28;26;38;40;25;44;43;37;42;29;30;48
DME24N
1
General
- Digital I/O card even which does not support 96kHz operation can handle 96kHz audio when "double channel mode" is set on the host machine. (Number of audio transmission channels halves in this mode.)
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- When MY8-ADDA96 is set to AE96 mode, do not set the host DME24N to double channel mode (it will not operate correctly).
AVIOM16/o-Y1, AVY16-ES,MY16-MD64
- AVIOM16/o-Y1, AVY16-ES and MY16-MD64 are supported with the software V1.2 or later.
MY16-CII
- Firmware V2.01 or later will be required in order to recognize MY16-CII card.
- Update is necessary for AVIOM6416Y2 with serial number earlier than #10099. For details, please refer to the following URL.
http://www.aviom.com/adspProduct6416y2.cfm?sec=products&cat=pro64&ln=6416y2
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY4-AEC
- In order to use MY4-AEC card, firmware V4.0 or later will be required.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
710
1020
200
110
80
90
100
3.75
304
1
22;24;21;23;33;34
DSP5D
2
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY16-MD64
- Use two cards (one master card and one slave cards) as one set.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
1420
2400
400
400
400
400
0
31.0199999999999
120
1
2;17;45;22;24;21;23;33;34
DM1000
2
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- Use MY8-ADDA96 in AE96 or AE mode.
MY16-MD64
- Use two cards (master and slave card) as one set.
MY16-CII
- MY16-CII is compliant with V2.30 or later.
- Y96K is compliant with V2.01 or later.
- You cannot store scenes using Y56K or Y96K to DM1000 scene memory 97-99.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
1420
620
400
400
400
400
0
25.1499999999999
116
1
17;45
LS9-32
2
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- Use MY8-ADDA96 by setting the mode to AE.
MY16-MD64
- Use two cards (one master card and one slave cards) as one set.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.]]>
1
1420
1000
400
400
200
200
100
20.3999999999999
113
1
2;17;45;22;24;21;23;33;34
SREV1
2
MY8-AD96
- MY8-AD96 is recognized as MY8-AD.
AP8-AD/AP8-DA
- AP8-AD/AP8-DA is recognized as "Unknown Card".]]>
1
500
0
400
400
200
200
50
13.5
306
2
4;6;7;9;10;11;12;14;16;17;18;19;36;20;39;41;45;24;46;21;23;27;28;26;38;40;25;44;43;37;42;33;34;29;30;47;48
AW4416
2
Y56K/Y96K
- AW4416 Firmware must be V2.0 or later to use Y56K
- Y96K will be recognized as Y56K.]]>
1
500
500
400
220
160
180
50
7.2
501
1
6;7;9;10;11;12;14;16;17;18;19;36;20;39;41;45;24;46;28;26;38;40;25;44;43;37;42;29;30;47;48
M7CL
3
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- Use MY8-ADDA96 by setting the mode to AE.
MY16-MD64
- MY16-MD64, use three cards (one master card and two slave cards) as one set.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.]]>
1
2130
3060
600
600
300
300
100
35.75
121
1
2;45;22;24;21;23;33;34
PM5D/PM5D-RH
4
General
- Digital I/O card even which does not support 96kHz operation can handle 96kHz audio when "double channel mode" is set on the host machine. (Number of audio transmission channels halves in this mode.)
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
- When using MY8-LAKE with the PM5D/PM5D-RH, a hardware upgrade for the PM5D/PM5D-RH is necessary.
Y96K
- System software V1.10 or later will be required in order to recognize Y96K card.
MY8-ADDA96
- Use MY8-ADDA96 by setting the mode to AE96 or AE.
- When MY8-ADDA96 is set to AE96 mode, do not set the host PM5D/PM5D-RH to double channel mode (it will not operate correctly).
MY16-MD64
- Use four MY16-MD64 cards (one master card and three slave cards) as one set.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
2840
4800
800
800
800
800
0
62.0399999999999
119
1
45;22;24;21;23;33
02R96
4
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- Use MY8-ADDA96 in AE96 or AE mode.
MY16-CII
- MY16-CII is compliant with V2.30 or later.
MY16-AE/-AT/-TD
- MY16-AE/-AT/-TD is compliant with V1.06 or later, and V2.0 or later is required to use all 16 channels for surround monitoring.
Y56K/96K
- Y56K/96K can be used either in Slot 4, 5, and/or 6.
- You cannot store scenes using Y56K or Y96K to 02R96 scene memory 97-99.
MY16-MD64
- Use four cards (One master and three slaves) as One set.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
2000
1000
800
800
600
600
80
39.2999999999999
117
1
17;45
DME64N
4
General
- Digital I/O card even which does not support 96kHz operation can handle 96kHz audio when "double channel mode" is set on the host machine. (Number of audio transmission channels halves in this mode.)
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- When MY8-ADDA96 is set to AE96 mode, do not set the host DME64N to double channel mode (it will not operate correctly).
AVIOM16/o-Y1, AVY16-ES
- AVIOM16/o-Y1, AVY16-ES are supported with the software V1.2 or later.
MY16-MD64
- MY16-MD64 are supported with the software V1.2 or later.
- Use four cards (one master card and three slave cards) as one set.
MY16-CII
- Firmware V2.01 or later will be required in order to recognize MY16-CII card.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY4-AEC
- In order to use MY4-AEC card, firmware V4.0 or later will be required.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
2840
4080
800
440
320
360
0
15
303
1
22;24;21;23;33;34
DME32
4
AP8-AD/AP8-DA
- DME32 unit with serial numbers starting from Q needs modification to be used with these cards. Please talk to your local Yamaha service center for details.
MY8-AD96 and MY8-DA96
- Fully supported with DME32 FirmwareV1.52 or later.
- With DME32 FirmwareV1.51 or before, MY8-AD96 and MY8-DA96 card names are not displayed.
MY8-ADDA96
- Use MY8-ADDA96 by setting the mode to AE.
RN.141.MY
- Use RN.141.MY by setting the mode to 8AE.]]>
1
1000
0
800
440
320
360
100
14.4
305
2
10;11;12;14;16;17;18;19;36;20;39;41;45;24;46;28;38;40;25;44;42;33;34;47;48
D24
4
AP8AD
- Only Slot 1 or 2 can be used.
- Only MY8-AT, MY8-TD, MY8-AE can be used in Slot 1 or 2 simultaneously with AP8AD.
AP8DA
- D24 firmware must be V2.0 or later to be used with AP8DA
- Only Slot 3 or 4 can be used.
- No other cards can be used in Slot 3 or 4 simultaneously with AP8DA.]]>
1
1000
0
800
800
800
800
30
12.0999999999999
504
2
6;7;9;10;11;12;14;16;17;18;19;36;20;39;41;45;24;46;27;28;26;38;40;25;44;43;37;42;33;34;29;30;47;48
DM2000
6
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-ADDA96
- Use MY8-ADDA96 in AE96 or AE mode.
MY16-MD64
- Use four cards (One master and three slaves) as One set.
MY16-CII
- MY16-CII is compliant with V2.30 or later.
MY16-AE/-AT/-TD
- MY16-AE/-AT/-TD is compliant with V1.14 or later and V2.0 or later is required to use all 16 channels for surround monitoring.
Y56K/Y96K
- Y96K is compliant with V2.11 or later.
- You cannot store scenes using Y56K or Y96K to DM2000 scene memory 97-99.
- Y56K/96K in Slot 4, 5, and/or 6.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).]]>
2
3000
1500
1200
1200
900
900
120
58.95
115
1
45
DIO8(PM1D)
8
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
MY8-AD96
- MY8-AD96 is recognized as MY8-AD24.
MY8-ADDA96
- Use MY8-ADDA96 by setting the mode to AE.
AVIOM16/o-Y1/AVIOM6416Y2/AVY16-ES/ AVY16-ES100/YG2/YS
- AVIOM16/o-Y1, AVIOM6416Y2, AVY16-ES, AVY16-ES100, YG2 and YS2 are recognized as YAMAHA 8ch MY card, and 8IN/8OUT audio data transmission is possible.
RN.141.MY
- Use RN.141.MY by setting the mode to 8AE.
Pivitec e16i/o-MY
- DIO8 only support 8 channels and will not be compatible with the initial release of the e16i/o-MY card.]]>
1
4000
1600
2400
1200
800
800
160
70.48
122
1
10;11;12;14;16;17;18;19;36;20;45;24;28;40;25;44;42;33;34;48
TX6n/TX5n/TX4n
1
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
MY8-AE96S
- Input channels of MY8-AE96S card cannot be selected as the word clock master when working at 88.2KHz/96KHz.]]>
2
780
400
400
200
80
90
0
4
401
2
2;13;14;15;16;17;39;41;45;22;24;21;23;27;28;44;33;34;29;30
CL5/ CL3/ CL1
3
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.]]>
1
2130
1200
1200
600
405
405
135
35.7599999999999
111
2
2;17;45;22;24;21;23;33;34
MTX5-D
1
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
Other
- External word clock supplied via a Mini-YGDAI card slot may cause noise in system configurations with multiple YDIF connections. In such cases, we recommend to choose another word clock source, such as Dante or YDIF.]]>
1
710
310
200
110
80
90
0
4
302
2
2;13;17;22;24;25;33;34;47
QL5/ QL1
2
1
1420
800
400
400
270
270
135
21.8399999999999
112
2
2;17;45;22;24;21;23;33;34;47
RSio64-D
4
General
- Double Channel mode (for higher sample rates) is not supported.
- If the card supports Native (or Generic) mode, set the switch on the card to Native (or Generic) to use with the RSio64-D.
MY8-LAKE
- Do not select as the word clock source for the RSio64-D: it will not work correctly.
MY8-AEB
- Set the AE/RSVD switch to the RSVD position on the card. If the card is selected as the word clock source for the RSio64-D, It synchronizes to input channel 7/8.
AVIOM16/o-Y1
- Select either 16ch or 8 ch mode, as this card will not work correctly in AVIOM mode. Do not select this card as the word clock source for RSio64-D when it is in 8ch mode: it will not work correctly.
Dugan-MY16
- Do not select this card as the word clock source for the RSio64-D when it is in LINK mode: it will not work correctly. In AUDIO mode, this card can be selected as the clock source so long as recognized ADAT signals are input.
- Do not enable the SRC of RSio64-D when the card is in LINK mode: it will work correctly.
WSG-Y16
- Do not select this card as the word clock source for the RSio64-D: it will not work correctly.]]>
1
2840
1600
800
800
540
540
0
24
201
2
2;17;45;22;24;21;23;33;34
MRX7-D
1
MY8-LAKE
- Input channels of MY8-LAKE card cannot be selected as the word clock master.
- As LAKE processing runs at 96kHz, SRC works automatically against 44.1kHz/88.2kHz audio signals.
RN.141.MY
- Use RN.141.MY by setting the mode to 16AT.
Other
- External word clock supplied via a Mini-YGDAI card slot may cause noise in system configurations with multiple YDIF connections. In such cases, we recommend to choose another word clock source, such as Dante or YDIF.]]>
1
710
310
200
110
80
90
0
4
301
2
2;13;17;22;24;25;31;32;47
CS-R10
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
101
2
2;13;17;45;22;24;21;23;33;34
DSP-R10
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
108
2
2;13;17;45;22;24;21;23;33;34
RPio622
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
109
2
2;13;17;45;22;24;21;23;33;34
RPio222
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
110
2
2;13;17;45;22;24;21;23;33;34
CS-R10-S
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
102
2
2;13;17;45;22;24;21;23;33;34
CSD-R7
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
103
2
2;13;17;45;22;24;21;23;33;34
CS-R5
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
104
2
2;13;17;45;22;24;21;23;33;34
CS-R3
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
105
2
2;13;17;45;22;24;21;23;33;34
DSP-RX
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
107
2
2;13;17;45;22;24;21;23;33;34
DSP-RX-EX
2
MY8-LAKE
- Do not select this card as the word clock source for the CS-R10: it will not work correctly.
Dante-MY16-AUD/Dante-MY16-AUD2
- Dante-MY16-AUD/Dante-MY16-AUD2 does not support the SINGLE mode when it is using high sampling (88.2kHz, 96kHz).
- HA remote control function is not supported.
AVY16-ES100
- HA remote control function is not supported.
MY16-ES64
- HA remote control function is not supported.
YG2
- HA remote control function is not supported.
RN.341.MY
- HA remote control function is not supported.
RN.141.MY
- HA remote control function is not supported.
]]>
2
1420
620
400
220
270
270
0
12
106
2